Low-Voltage Current Transformers (0.72 kV max.)

POS SERIES

About the Product

The POS Series window-type low-voltage current transformers, intended for 600V (max.) power systems, are appropriate for electric engineering applications and distribution switchgears. Every POS Series current transformer is contained in an ABS exterior (self-extinguishing) and encloses a high-quality coil, along with an annealed oriented core – all manufactured for rated accuracy and output. On the primary side, wiring can be done with a busbar or with insulated wire. Compact and lightweight, each of these current transformers can be installed either horizontally or vertically; in addition, the product is designed in such a way that installation in a smaller space (e.g. in a motor control center) poses no difficulty for secondary wiring or fastening the CT base. The range of Rated Burden is from 1.0 VA to 40 VA, and the Accuracy is Class 0.5, 1.0, or 3.0, depending on the Primary Ampere-Turn (AT). The POS Series products meet various international standards and have consistently earned a high level of customer satisfaction.

Specifications

  • Standards: IEC, IEEE
  • Rated Voltage: ≤ 0.72 kV
  • Frequency: 50 / 60 Hz
  • AC/BIL: 3 / – kV
  • For indoor applications
  • Self-extinguishing ABS exterior provides a high level of insulation and excellent moisture resistance
  • Compact and lightweight – ideal for wiring and installation in smaller spaces
  • Top-facing terminals for easy wiring
  • Terminal covers (optional)
  • Other Standards and Specifications available

Selection Table

Burden (VA) & Accuracy (Class) *

Rated Burden: 1 ~ 40 VA

Accuracy: 0.5, 1.0 & 3.0 CL.

Model

Primary Ampere-Turn (AT) **

Secondary Current (A)

POS-30R

75 ~ 300

 

 

 

 

5 or 1

POS-50R

 

100 ~ 500

 

 

 

POS-70R

 

 

300 ~ 800

 

 

POS-90R

 

 

 

500 ~ 2000

 

POS-120R

 

 

 

 

800 ~ 3200

* The Burden (VA) and its corresponding Accuracy (Class) are determined by the Primary Ampere-Turn (AT) of the Current Transformer.

** Primary Ampere-Turn (AT) = Primary Current (A) x Primary Turns (T).

 
 

Downloadables

Low-Voltage Current Transformers, POS Series

Easy-to-print document, containing product description, specifications, and a selection table.